{"product_id":"heatrae-sadia-2500-litre-megaflo-indirect-unvented-cylinder-10-bar-45050579","title":"Heatrae Sadia 2500 Litre Megaflo Indirect Unvented Cylinder 10 Bar 45050579","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003eThis product is sourced directly from the supplier. Please \u003ca rel=\"noopener\" title=\"Contact Us\" href=\"https:\/\/arcanu.com\/pages\/contact-us\" target=\"_blank\"\u003eget in touch\u003c\/a\u003e, and we'll confirm delivery details.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"_p_13sb5_107\"\u003e\n\u003cspan\u003eAt 2,500 litres and rated to 10 bar working pressure, the Heatrae Sadia Megaflo Indirect Unvented Cylinder (45050579) is engineered to meet the hot water demands of the most intensive commercial environments.  \u003c\/span\u003e\u003cspan\u003eThe inner vessel is fabricated from duplex stainless steel, ensuring long-term structural integrity and reliable performance under sustained commercial load.\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"_p_13sb5_107\"\u003e\u003cspan\u003eFrom hotels and hospitals to care homes, leisure centres, and large HMOs, the Megaflo 2500 Litre (45050579) is built for commercial environments where hot water supply cannot be interrupted. Indirect heating via an internal primary circuit coil ensures compatibility with gas, oil, and heat pump systems, while the fully unvented configuration delivers balanced mains pressure to every outlet in the building.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2500 Litre Storage Capacity\u003c\/strong\u003e - \u003cspan\u003eDelivers the hot water volume required to support demanding commercial draw-off networks, maintaining consistent pressure and flow rate across multiple simultaneous outlets without interruption.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains Pressure Performance (Up to 10 Bar)\u003c\/strong\u003e - \u003cspan\u003eOperates at full mains pressure throughout, eliminating the need for a cold water storage cistern or header tank and ensuring a powerful, balanced supply to every outlet in the system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndirect Heating\u003c\/strong\u003e - \u003cspan\u003eStored water is heated via an internal coil connected to a boiler or heat pump, keeping the heat source separate from the stored volume and ensuring compatibility with gas, oil, and renewable primary systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnvented System - No Cold Water Tank Required\u003c\/strong\u003e - \u003cspan\u003eConnected directly to the mains, the system requires no roof-mounted or plant room cistern, freeing up space and simplifying the overall installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuplex Stainless Steel Inner Vessel\u003c\/strong\u003e - \u003cspan\u003eThe duplex stainless steel inner vessel withstands the demands of continuous commercial operation, offering strong corrosion resistance, a long service life, and stable performance regardless of local water quality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Thermal Insulation\u003c\/strong\u003e - \u003cspan\u003eA CFC-free foam-insulated outer jacket minimises standing heat losses between cycles, reducing the energy required to maintain stored water at temperature.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry-Leading Heat Recovery\u003c\/strong\u003e - \u003cspan\u003eSuper coil heat exchangers maintain recovery times of under 60 minutes across all models, keeping the hot water supply continuous and reliable even under prolonged peak demand.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 330.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38%; height: 19.5938px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"width: 62%; height: 19.5938px;\"\u003eIndirect Unvented Hot Water Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eHeatrae Sadia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eMegaflo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003e2500 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eHeating Method\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eIndirect (internal coil, primary circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003e10 Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eUnvented (mains pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003e2419mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003e1470mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.1875px;\"\u003e\n\u003ctd style=\"height: 67.1875px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 67.1875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEmpty: 450kg\u003c\/li\u003e\n\u003cli\u003eFull: 2950kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.1875px;\"\u003e\n\u003ctd style=\"height: 67.1875px;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"height: 67.1875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eInner Vessel: Duplex stainless steel\u003c\/li\u003e\n\u003cli\u003eOuter Casing: CFC-free foam insulated jacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003ePart Code\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\"\u003e45050579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Arcanu","offers":[{"title":"Default Title","offer_id":54834976227596,"sku":"H14.C63.02548","price":12999.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/6429\/7228\/files\/H14.C63.02548.jpg?v=1781619890","url":"https:\/\/arcanu.com\/products\/heatrae-sadia-2500-litre-megaflo-indirect-unvented-cylinder-10-bar-45050579","provider":"Arcanu","version":"1.0","type":"link"}