{"product_id":"22mm-automatic-bypass-valve-angle","title":"22mm Automatic Bypass Valve | Angled | Compression Connections","description":"\u003cp\u003eZone valves closing shouldn't mean your pump is running against a dead end. The \u003cstrong\u003e22mm Automatic Bypass Valve\u003c\/strong\u003e in an angled configuration maintains a minimum flow path when controls shut off circuits, keeping the pump protected and system pressure balanced. The visual pressure indicator takes the guesswork out of setting the differential pressure, and the 0.1 to 0.5 bar adjustment range covers most sealed heating system requirements.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e22mm automatic bypass valve\u003c\/strong\u003e with angled design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e22mm compression connections\u003c\/strong\u003e for straightforward installation\u003c\/li\u003e\n\u003cli\u003eMaintains adequate flow when \u003cstrong\u003ezone valves close\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtects pumps from \u003cstrong\u003eoperating against a closed head\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjustable differential pressure range of \u003cstrong\u003e0.1 to 0.5 bar\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVisual pressure indicator for easy adjustment\u003c\/li\u003e\n\u003cli\u003eFlow capacity of up to \u003cstrong\u003e5 m³\/h (approximately 83 litres\/minute)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReduces system noise and helps maintain even system pressure\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure: \u003cstrong\u003e10 bar\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum working temperature: \u003cstrong\u003e100°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003esealed central heating systems and boiler installations\u003c\/strong\u003e where an automatic bypass is required to maintain circulation. Particularly useful in systems with zone valves or other controls that can restrict or shut off water flow.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Bypass Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACE5701\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSize\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngled differential bypass valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnections\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22mm Compression\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustment Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–0.5 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlow Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–5 m³\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. Maximum Flow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e83 litres\/minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Working Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Working Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeating and sealed systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Arcanu","offers":[{"title":"Default Title","offer_id":62085511741708,"sku":"A28.B80.02757","price":7.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/6429\/7228\/files\/A28.B80.02757.jpg?v=1789720007","url":"https:\/\/arcanu.com\/products\/22mm-automatic-bypass-valve-angle","provider":"Arcanu","version":"1.0","type":"link"}